Skip to main content

Calcu.fit

Magnetic Flux Converter

The Magnetic Flux Converter is a useful online tool for converting magnetic flux measurements between different units. Magnetic flux describes the total magnetic field passing through a particular surface. It is an important concept in electromagnetism, electrical engineering, physics, transformers, electric motors, and magnetic circuit design The SI unit of magnetic flux is the weber (Wb), while the maxwell (Mx) is a traditional unit used in the centimetre-gram-second (CGS) system. Smaller and larger units, such as microweber, milliweber, and kiloweber, are also useful for expressing magnetic flux values across different applications This converter makes it easy to change magnetic flux measurements from one unit into another without performing manual calculations. Whether you are studying electromagnetism, working with magnetic components, or comparing scientific measurements, converting between magnetic flux units helps you understand and use the values correctly Important: Magnetic flux is different from magnetic flux density and magnetic field strength. These quantities are related, but they measure different properties of a magnetic field.

Magnetic Flux Converter

Enter your value

Select the magnetic flux units you want to convert.

Converted value
100,000,000
Maxwell (Mx)
Conversion factor100,000,000
Base value (Weber)1 Wb

Common conversions

Magnetic flux measures the total magnetic field passing through a given surface. Its SI unit is the weber (Wb). One weber is equal to 100,000,000 maxwells. One weber is also equivalent to one volt-second. Results are calculated using standard conversion factors.

What Is Magnetic Flux?

Magnetic flux is the measurement of the total magnetic field passing through a specified surface. It indicates how much magnetic field crosses an area and depends on the magnetic field strength, the surface area, and the angle between the magnetic field and the surface.

Magnetic flux is represented by the Greek letter phi (\(\Phi\)) and its SI unit is the weber (Wb).

For a uniform magnetic field passing through a flat surface, magnetic flux is calculated using:

\[ \Phi = B A \cos(\theta) \]

Where:

  • \(\Phi\) = Magnetic flux in webers (Wb)

  • B = Magnetic flux density in tesla (T)

  • A = Surface area in square metres (m²)

  • \(\theta\) = Angle between the magnetic field and the surface normal

For example, if a magnetic field density of 0.5 tesla passes perpendicularly through an area of 2 square metres:

\[ \Phi = 0.5 \times 2 \times \cos(0^\circ) \]
\[ \Phi = 1\ Wb \]

The magnetic flux is therefore 1 weber.

How to Use the Magnetic Flux Converter

Using the Magnetic Flux Converter is straightforward:

  1. Enter the magnetic flux value you want to convert.

  2. Select the original unit from the From dropdown menu.

  3. Choose the target unit from the To dropdown menu.

  4. The converter calculates the equivalent magnetic flux value.

  5. Review the result and use it in your calculations or reference.

For example, entering 1 weber and selecting maxwell as the target unit gives a result of 100,000,000 maxwells.

Complete Magnetic Flux Units Supported by the Converter

The linked UnitConverters.net page supports 13 magnetic flux units. The weber (Wb) is the reference unit for all conversions.

1. Weber (Wb)

The weber is the SI unit of magnetic flux. It represents the magnetic flux associated with an induced voltage of one volt when the flux changes at a rate of one weber per second in a single-turn circuit.

\[ 1\ Wb = 1\ V \cdot s \]

2. Milliweber (mWb)

A milliweber is one-thousandth of a weber.

\[ 1\ mWb = 0.001\ Wb \]

It is useful for expressing smaller magnetic flux measurements.

3. Microweber (µWb)

A microweber is one-millionth of a weber.

\[ 1\ \mu Wb = 0.000001\ Wb \]

4. Volt-Second (V·s)

Volt-second is an equivalent unit of magnetic flux based on the relationship between voltage and changing magnetic flux.

\[ 1\ V \cdot s = 1\ Wb \]

5. Unit Pole

The unit pole is a historical CGS-related magnetic unit used in older electromagnetic references.

\[ 1\ unit\ pole \approx 1.256637061436 \times 10^{-7}\ Wb \]

6. Megaline

A megaline is equal to ten million magnetic lines of flux.

\[ 1\ megaline = 0.01\ Wb \]

7. Kiloline

A kiloline represents one thousand magnetic lines of flux.

\[ 1\ kiloline = 0.00001\ Wb \]

8. Line

The line is a traditional CGS unit of magnetic flux.

\[ 1\ line = 10^{-8}\ Wb \]

9. Maxwell (Mx)

The maxwell is a CGS unit of magnetic flux named after physicist James Clerk Maxwell.

\[ 1\ Mx = 10^{-8}\ Wb \]

It is commonly found in older magnetic measurement references.

10. Tesla Square Meter (T·m²)

Tesla square meter represents magnetic flux density multiplied by surface area.

\[ 1\ T \cdot m^2 = 1\ Wb \]

11. Tesla Square Centimeter (T·cm²)

This unit expresses magnetic flux density in tesla over an area measured in square centimetres.

\[ 1\ T \cdot cm^2 = 0.0001\ Wb \]

12. Gauss Square Centimeter (G·cm²)

Gauss square centimeter is a traditional CGS-based expression of magnetic flux.

\[ 1\ G \cdot cm^2 = 10^{-8}\ Wb \]

13. Magnetic Flux Quantum (Φ₀)

The magnetic flux quantum is a fundamental quantity in quantum physics and superconductivity. It represents the smallest quantum of magnetic flux associated with a superconducting flux quantum.

\[ 1\ \Phi_0 \approx 2.06783461 \times 10^{-15}\ Wb \]

Magnetic Flux Conversion Formula

The weber is the reference unit for converting magnetic flux measurements. To convert between any two supported units, first express the original value in webers and then convert it into the target unit.

The main conversion relationships include:

\[ 1\ Wb = 10^8\ Mx \]
\[ 1\ Wb = 1000\ mWb \]
\[ 1\ Wb = 1,000,000\ \mu Wb \]

Weber to Maxwell

To convert webers into maxwells, multiply the value by 100,000,000.

\[ Mx = Wb \times 10^8 \]

Example: Convert 2 Wb into Mx

Given:

\[ Wb = 2 \]

Calculation:

\[ 2 \times 100,000,000 = 200,000,000 \]

Result:

\[ 2\ Wb = 200,000,000\ Mx \]

Maxwell to Weber

To convert maxwells into webers, divide the value by 100,000,000.

\[ Wb = \frac{Mx}{10^8} \]

Example: Convert 50,000,000 Mx into Wb

\[ 50,000,000 \div 100,000,000 = 0.5 \]

Result:

\[ 50,000,000\ Mx = 0.5\ Wb \]

Weber to Milliweber

Multiply the weber value by 1,000.

\[ mWb = Wb \times 1000 \]

Example: Convert 0.75 Wb into mWb

\[ 0.75 \times 1000 = 750 \]

Result:

\[ 0.75\ Wb = 750\ mWb \]

Weber to Microweber

Multiply the weber value by 1,000,000.

\[ \mu Wb = Wb \times 1,000,000 \]

Example: Convert 0.025 Wb into µWb

\[ 0.025 \times 1,000,000 = 25,000 \]

Result:

\[ 0.025\ Wb = 25,000\ \mu Wb \]

Magnetic Flux Conversion Table

The following table includes all 13 units supported by the reference converter and their equivalent values in webers.

 

Unit

Symbol

Equivalent in Wb

Weber

Wb

1

Milliweber

mWb

0.001

Microweber

µWb

0.000001

Volt-second

V·s

1

Unit pole

—

1.256637061436 × 10⁻⁷

Megaline

—

0.01

Kiloline

—

0.00001

Line

—

0.00000001

Maxwell

Mx

0.00000001

Tesla square meter

T·m²

1

Tesla square centimeter

T·cm²

0.0001

Gauss square centimeter

G·cm²

0.00000001

Magnetic flux quantum

Φ₀

2.06783461 × 10⁻¹⁵

Common Magnetic Flux Conversions

Conversion

Result

1 Wb to mWb

1,000 mWb

1 Wb to µWb

1,000,000 µWb

1 Wb to Mx

100,000,000 Mx

1 Mx to Wb

0.00000001 Wb

1 Wb to V·s

1 V·s

1 Wb to T·m²

1 T·m²

1 Wb to T·cm²

10,000 T·cm²

1 Wb to G·cm²

100,000,000 G·cm²

1 Wb to megaline

100 megalines

1 Wb to kiloline

100,000 kilolines

1 Wb to line

100,000,000 lines

Weber to Maxwell Conversion Chart

This chart provides common conversion values between the SI unit weber and the traditional CGS unit maxwell.

 

Weber (Wb)

Maxwell (Mx)

0.01

1,000,000

0.1

10,000,000

0.5

50,000,000

1

100,000,000

2

200,000,000

5

500,000,000

10

1,000,000,000

20

2,000,000,000

50

5,000,000,000

100

10,000,000,000

500

50,000,000,000

1,000

100,000,000,000

Understanding Magnetic Flux and Magnetic Flux Density

Magnetic flux and magnetic flux density are closely related, but they describe different properties of a magnetic field.

Magnetic Flux (Φ)

Magnetic flux measures the total magnetic field passing through a particular surface. Its SI unit is the weber (Wb).

Magnetic Flux Density (B)

Magnetic flux density measures the amount of magnetic flux passing through a unit area. Its SI unit is the tesla (T).

\[ B = \frac{\Phi}{A} \]

Where:

  • B = Magnetic flux density in tesla

  • Φ = Magnetic flux in webers

  • A = Surface area in square metres

For a uniform magnetic field perpendicular to a surface:

\[ \Phi = B \times A \]

For example, if a magnetic flux density of 0.4 T passes perpendicularly through an area of 0.5 m²:

\[ \Phi = 0.4 \times 0.5 \]
\[ \Phi = 0.2\ Wb \]

Difference Between Magnetic Flux and Magnetic Flux Density

Feature

Magnetic Flux

Magnetic Flux Density

Symbol

Φ

B

Meaning

Total magnetic field through a surface

Magnetic flux per unit area

SI unit

Weber (Wb)

Tesla (T)

Related formula

Φ = B × A

B = Φ / A

Measurement

Total flux

Flux concentration over an area

Faraday’s Law of Electromagnetic Induction

Magnetic flux plays an important role in electromagnetic induction. Faraday’s law explains how a changing magnetic flux through a coil produces an induced electromotive force (EMF).

For a coil with N turns:

\[ \mathcal{E} = -N\frac{d\Phi}{dt} \]

Where:

  • \(\mathcal{E}\) = Induced electromotive force in volts

  • N = Number of coil turns

  • \(d\Phi/dt\) = Rate of change of magnetic flux

  • The negative sign represents Lenz’s law

Worked Example

Suppose the magnetic flux through each turn of a 100-turn coil changes from 0.02 Wb to 0.08 Wb in 0.2 seconds.

First, calculate the change in flux:

\[ \Delta\Phi = 0.08 – 0.02 = 0.06\ Wb \]

Calculate the average magnitude of induced EMF:

\[ |\mathcal{E}| = N \times \frac{\Delta\Phi}{\Delta t} \]
\[ |\mathcal{E}| = 100 \times \frac{0.06}{0.2} \]
\[ |\mathcal{E}| = 30\ V \]

The average induced EMF magnitude is 30 volts.

Applications of Magnetic Flux Measurements

1. Transformer Design

Transformers rely on changing magnetic flux to transfer electrical energy between primary and secondary windings. Engineers calculate and monitor magnetic flux when designing transformer cores and windings.

2. Electric Motors

Electric motors use magnetic fields to generate rotational movement. Magnetic flux calculations help engineers analyze motor performance, magnetic circuits, and electromagnetic interactions.

3. Electrical Generators

Generators produce electricity through electromagnetic induction. A changing magnetic flux through coils generates an induced voltage.

4. Inductors and Coils

Inductors store energy in magnetic fields. Magnetic flux is important when studying inductance, coil behavior, and electromagnetic energy storage.

5. Magnetic Sensors

Magnetic sensors detect changes in magnetic fields and flux. They are used in industrial equipment, position sensors, measurement instruments, and electronic devices.

6. Superconductivity Research

Magnetic flux quantum measurements are important in superconductivity research and quantum physics. Researchers study quantized magnetic flux in superconducting materials and devices.

7. Electromagnetic Research

Scientists use magnetic flux measurements to study electromagnetic induction, magnetic field behavior, and the interaction between magnetic fields and materials.

Advantages of Using an Online Magnetic Flux Converter

  • Quick conversions: Convert magnetic flux values without performing manual calculations.

  • Multiple units: Work with SI, CGS, and other supported magnetic flux units.

  • Convenient comparisons: Compare weber, maxwell, volt-second, and other measurements.

  • Reduced calculation errors: Use consistent conversion factors.

  • Educational support: Understand magnetic flux relationships and formulas.

  • Engineering convenience: Simplify calculations involving transformers, motors, coils, and magnetic systems.

Limitations and Important Considerations

Although an online magnetic flux converter is useful, it has some limitations.

  • It does not measure magnetic flux: It only converts values that you enter.

  • It does not measure magnetic flux density: Flux density requires its own measurement or calculation.

  • Surface area matters: Calculating flux from magnetic flux density requires the surface area and field orientation.

  • Magnetic field direction matters: The angle between the magnetic field and surface normal affects the flux calculation.

  • It does not calculate induced voltage automatically: Faraday’s law also requires the number of turns and the rate of flux change.

  • Precision matters: Some scientific applications require more significant digits than a basic display provides.

For professional electrical engineering and scientific applications, verify important calculations using appropriate technical references and measurement methods.

Frequently Asked Questions (FAQ)

What is a magnetic flux converter?

A magnetic flux converter is an online tool that converts magnetic flux measurements between different units, including weber, maxwell, milliweber, microweber, and volt-second.

The SI unit of magnetic flux is the weber (Wb). It measures the total magnetic flux passing through a specified surface.

One weber is equal to 100,000,000 maxwells. \[ 1\ Wb = 10^8\ Mx \]

 Divide the maxwell value by 100,000,000. For example: \[ 50,000,000 \div 100,000,000 = 0.5\ Wb \]

One weber equals 1,000 milliwebers. \[ 1\ Wb = 1000\ mWb \]

A microweber is one-millionth of a weber. It is used to express relatively small magnetic flux values. \[ 1\ \mu Wb = 10^{-6}\ Wb \]

Yes. Volt-second and weber are equivalent units of magnetic flux. \[ 1\ V \cdot s = 1\ Wb \]

Magnetic flux represents the total magnetic field passing through a surface, while magnetic flux density represents magnetic flux per unit area. Weber measures flux, and tesla measures flux density.

A magnetic flux quantum is a fundamental quantity associated with superconductivity and quantum physics. Its value is approximately: \[ \Phi_0 = 2.06783461 \times 10^{-15}\ Wb \]

Magnetic flux is used in transformer design, electric motors, generators, inductors, magnetic sensors, electromagnetic research, and superconductivity studies

An online magnetic flux converter saves time and helps reduce manual conversion errors. It makes it easier to compare measurements expressed in SI, CGS, and other supported units.

Disclaimer

The Magnetic Flux Converter is provided for educational and general informational purposes. Conversion results are based on standard mathematical relationships between magnetic flux units This calculator does not measure magnetic flux or magnetic field strength and does not replace professional engineering analysis. Actual magnetic flux calculations may require information about magnetic field density, surface area, and field orientation Always verify important scientific and engineering calculations before using them in professional or safety-critical applications.