The Inductance Converter is a useful online tool for converting inductance measurements between different units. Inductance is an important property of electrical circuits that describes the ability of a conductor or coil to oppose changes in electric current by producing an induced electromotive force. It plays a major role in electrical engineering, electronics, power systems, transformers, motors, and communication equipment The standard SI unit of inductance is the henry (H), named after the American scientist Joseph Henry. However, many practical inductors have values much smaller than one henry. For this reason, electrical components are commonly specified in millihenries (mH), microhenries (µH), and nanohenries (nH) Our Inductance Converter makes it easy to convert between these measurement units. Enter an inductance value, select its current unit, choose the unit you want to convert to, and obtain the equivalent measurement without performing complicated manual calculations.
Select the inductance units you want to convert.
Inductance is the property of an electrical conductor or coil that opposes changes in electric current by producing an induced electromotive force. Its SI unit is the henry (H). One henry is equal to 1,000 millihenries, 1,000,000 microhenries, or 1,000,000,000 nanohenries. Results are calculated using standard conversion factors.
Inductance is the property of an electrical conductor or coil that opposes changes in the current flowing through it. When current passes through a coil, it creates a magnetic field around the conductor. If the current changes, the magnetic field also changes, inducing a voltage in the coil.
This effect is known as electromagnetic induction. Inductance is important in components such as inductors, transformers, electric motors, generators, and electrical filters.
The standard SI unit of inductance is the henry (H).
The basic relationship between inductance, magnetic flux, and current is:
Where:
L = Inductance in henries (H)
N = Number of turns in the coil
Φ = Magnetic flux through each turn, in webers (Wb)
I = Current flowing through the coil, in amperes (A)
For a linear inductor, the voltage relationship is:
Where:
V = Induced voltage in volts
L = Inductance in henries
dI/dt = Rate of change of current over time
The induced voltage acts in a direction that opposes the change in current.
The converter makes it easy to change inductance measurements from one unit to another.
Enter the value: Type the inductance measurement you want to convert.
Select the source unit: Choose the original unit, such as henry, millihenry, or microhenry.
Select the target unit: Choose the unit you want to convert the measurement into.
Calculate: The converter applies the appropriate conversion factor.
Read the result: Review the equivalent inductance value.
You can use the tool for common electronic component values as well as very large or very small inductance measurements.
The henry is the standard SI unit of inductance. Other units are formed using metric prefixes or belong to older electromagnetic measurement systems.
The following table lists the units supported by the reference converter and their equivalent values in henries.
Unit | Symbol | Equivalent in Henries |
|---|---|---|
Henry | H | 1 H |
Exahenry | EH | 1 × 10¹⁸ H |
Petahenry | PH | 1 × 10¹⁵ H |
Terahenry | TH | 1 × 10¹² H |
Gigahenry | GH | 1 × 10⁹ H |
Megahenry | MH | 1 × 10⁶ H |
Kilohenry | kH | 1 × 10³ H |
Hectohenry | hH | 100 H |
Dekahenry | daH | 10 H |
Decihenry | dH | 0.1 H |
Centihenry | cH | 0.01 H |
Millihenry | mH | 0.001 H |
Microhenry | µH | 1 × 10⁻⁶ H |
Nanohenry | nH | 1 × 10⁻⁹ H |
Picohenry | pH | 1 × 10⁻¹² H |
Femtohenry | fH | 1 × 10⁻¹⁵ H |
Attohenry | aH | 1 × 10⁻¹⁸ H |
Weber per ampere | Wb/A | 1 H |
Abhenry | abH | 1 × 10⁻⁹ H |
EMU of inductance | — | 1 × 10⁻⁹ H |
Stathenry | stH | 898,755,200,000 H |
ESU of inductance | — | 898,755,200,000 H |
These are the conversion factors listed by the reference converter.
To convert an inductance measurement between two units, first express the original value in henries. Then divide that value by the number of henries represented by one unit of the target measurement.
The general formula is:
Where:
Original Value = The measurement you want to convert.
Source Factor = Number of henries in one source unit.
Target Factor = Number of henries in one target unit.
Target Value = The converted measurement.
Convert 5 henries (H) into millihenries (mH).
The conversion relationship is:
Calculation:
Result: 5 H = 5,000 mH
Convert 250 millihenries (mH) into henries (H).
Result: 250 mH = 0.25 H
Convert 750 microhenries (µH) into millihenries (mH).
Result: 750 µH = 0.75 mH
Convert 4,500 nanohenries (nH) into microhenries (µH).
Result: 4,500 nH = 4.5 µH
Convert 2.5 henries into microhenries.
Result: 2.5 H = 2,500,000 µH
Convert 1 henry into stathenries (stH).
According to the reference conversion factor:
Therefore:
Result: 1 H ≈ 1.11265 × 10⁻¹² stH
The following table shows frequently used inductance conversions, especially those involving henries, millihenries, microhenries, and nanohenries.
From | To | Conversion |
|---|---|---|
1 H | Millihenry | 1,000 mH |
1 H | Microhenry | 1,000,000 µH |
1 H | Nanohenry | 1,000,000,000 nH |
1 H | Picohenry | 1,000,000,000,000 pH |
1 mH | Henry | 0.001 H |
1 mH | Microhenry | 1,000 µH |
1 µH | Henry | 0.000001 H |
1 µH | Nanohenry | 1,000 nH |
1 nH | Microhenry | 0.001 µH |
1 nH | Picohenry | 1,000 pH |
1 kH | Henry | 1,000 H |
1 abH | Henry | 0.000000001 H |
The henry is the standard SI unit of inductance. An inductor has an inductance of one henry when a current change of one ampere per second produces an induced voltage of one volt in the ideal case.
Henries are used in electrical engineering, power systems, magnetic components, and theoretical calculations.
One exahenry equals \(10^{18}\) henries. It is an extremely large unit and is primarily useful for representing exceptionally large theoretical quantities.
A petahenry equals \(10^{15}\) henries. It is another very large metric unit that is not commonly used to specify ordinary electrical components.
One terahenry equals \(10^{12}\) henries. It represents an extremely large inductance value.
A gigahenry equals one billion henries. This unit is mainly relevant to mathematical representations and very large quantities.
One megahenry equals one million henries. It is a large metric multiple of the standard inductance unit.
A kilohenry equals 1,000 henries. The prefix kilo represents one thousand.
One hectohenry equals 100 henries. The prefix hecto represents one hundred.
A dekahenry equals 10 henries. It represents ten times the standard unit.
One decihenry equals 0.1 henry, or one-tenth of a henry.
A centihenry equals 0.01 henry, or one-hundredth of a henry.
One millihenry equals 0.001 henry. Millihenries are commonly used to describe inductors in filters, power supplies, and electronic circuits.
A microhenry equals one-millionth of a henry. It is widely used for inductors in switching power supplies, radio-frequency circuits, and electronic equipment.
One nanohenry equals one-billionth of a henry. Nanohenries are useful when describing small inductances in high-frequency circuits, circuit-board traces, and compact electronic components.
A picohenry equals one-trillionth of a henry. It is used when dealing with extremely small inductances, particularly in high-frequency and microwave engineering.
One femtohenry equals \(10^{-15}\) henries. It is an extremely small unit that can be relevant in advanced electronic and semiconductor applications.
An attohenry equals \(10^{-18}\) henries. It is primarily useful for representing extremely small inductance values in specialized research and theoretical applications.
Weber per ampere is another way to express inductance. Since inductance is related to magnetic flux divided by current, one weber per ampere is exactly equal to one henry.
The abhenry is a unit of inductance associated with the electromagnetic CGS system. One abhenry equals \(10^{-9}\) henries.
EMU stands for electromagnetic unit. The EMU of inductance is an older electromagnetic measurement unit and has the same conversion factor as the abhenry in this converter.
The stathenry is a unit associated with the electrostatic CGS system. One stathenry equals 898,755,200,000 henries according to the reference converter.
ESU stands for electrostatic unit. The ESU of inductance is another designation for the electrostatic inductance unit and has the same conversion factor as the stathenry.
Inductance conversion is useful in electrical engineering, electronics, component selection, circuit design, and technical education. Different components and technical documents may express inductance using different units.
Inductors are used in many electronic circuits, including filters, oscillators, and signal-processing systems. Converting inductance values helps engineers work with circuit specifications and select appropriate components.
Inductors are important components in switching power supplies and voltage converters. Their inductance affects current ripple, energy storage, and circuit performance.
Inductance is an important consideration in transformer design. Engineers work with magnetic flux, winding characteristics, and inductance values when developing transformer systems.
Radio-frequency circuits often use small inductance values expressed in microhenries or nanohenries. Accurate conversions help when working with tuning circuits, antennas, and high-frequency components.
Students use inductance conversions when solving physics and electrical engineering problems. Understanding the relationships between henries, millihenries, and microhenries makes calculations easier.
Manufacturers may specify inductor values using different units. Converting these measurements helps users compare components and understand their electrical specifications.
The inductance of a coil depends on its physical construction, magnetic properties, and operating conditions.
The number of turns in a coil strongly affects its inductance. For an ideal coil with unchanged geometry and core material, inductance generally increases with the square of the number of turns.
The material inside a coil can influence its magnetic properties and inductance. Iron, ferrite, and air cores have different magnetic characteristics.
The cross-sectional area of a coil affects the magnetic flux it can produce. A larger area can increase inductance when other conditions remain constant.
The length of a coil influences its magnetic field and inductance. For a simplified long solenoid, increasing the coil length while keeping other factors constant generally reduces inductance.
Magnetic permeability describes how easily a material supports the formation of a magnetic field. A core material with higher permeability can increase the inductance of a coil.
The effective behavior of an inductor can change with frequency because of parasitic capacitance, resistance, and core losses. These effects are particularly important in high-frequency applications.
Inductance, capacitance, and resistance are three important electrical properties. They affect how current and voltage behave in an electrical circuit, but each describes a different characteristic.
Property | Meaning | SI Unit |
|---|---|---|
Inductance | Opposition to changes in current through electromagnetic induction | Henry (H) |
Capacitance | Ability to store electrical charge per unit voltage | Farad (F) |
Resistance | Opposition to the flow of electric current | Ohm (Ω) |
Inductance is associated with magnetic fields, capacitance with electric fields and stored charge, and resistance with electrical energy dissipation.
Inductance conversions involve powers of ten, so choosing the wrong unit or conversion factor can produce a significant error.
Confusing millihenry and microhenry: One millihenry equals 1,000 microhenries.
Mixing up microhenry and nanohenry: One microhenry equals 1,000 nanohenries.
Moving the decimal point incorrectly: Always check whether the target unit is larger or smaller than the original unit.
Ignoring unit symbols: H, mH, µH, and nH represent different measurement scales.
Using the wrong conversion factor: Confirm the source and target units before calculating.
Rounding too early: Keep sufficient decimal places when converting very small inductance values.
Confusing inductance with impedance: Inductance is measured in henries, while impedance is measured in ohms.
Using an online Inductance Converter can help reduce calculation mistakes and make unit conversions faster.
An Inductance Converter is an online tool that converts inductance measurements between different units, including henries, millihenries, microhenries, nanohenries, and other supported units.
The henry (H) is the standard SI unit of inductance. It describes the relationship between a changing electrical current and the voltage induced in a circuit.
One henry equals 1,000 millihenries. \[ 1\ H=1000\ mH \]
One millihenry equals 1,000 microhenries. \[ 1\ mH=1000\ \mu H \]
One microhenry equals 1,000 nanohenries. \[ 1\ \mu H=1000\ nH \]
Multiply the microhenry value by 0.000001. For example: \[ 250\ \mu H\times0.000001=0.00025\ H \] Therefore, 250 microhenries equals 0.00025 henries.
An inductor stores energy in a magnetic field when current flows through it. It also opposes changes in current and is commonly used in filters, power supplies, transformers, and electronic circuits.
Inductance is a property of a circuit or component that describes its response to changing current and is measured in henries. Impedance describes the total opposition to alternating current and is measured in ohms.
Inductance depends on the number of coil turns, coil dimensions, core material, magnetic permeability, and operating conditions.
Yes. One nanohenry equals 1,000 picohenries. \[ 1\ nH=1000\ pH \]
Yes. The Calcu.fit Inductance Converter is intended to provide a simple way to convert between supported inductance units without manually calculating conversion factors.
A few of the most-used tools in each hub.
The Inductance Converter is provided for general educational and informational purposes. Although every effort is made to provide accurate conversion results, users should verify important measurements and calculations before using them in professional engineering, electrical installations, or safety-critical applications. Calcu.fit does not guarantee that every result is suitable for a particular technical application.