The Magnetic Field Strength Converter is an online tool for converting magnetic field strength measurements between different units. Magnetic field strength, also known as magnetic field intensity, describes the magnetizing force produced by electric currents and magnetic materials. It is an important concept in electromagnetism, electrical engineering, physics, and magnetic circuit design Magnetic field strength is commonly represented by the symbol H and measured in amperes per meter (A/m) in the International System of Units (SI). Another unit, the oersted (Oe), is used in the centimetre-gram-second (CGS) system This converter makes it easier to change values between magnetic field strength units without performing manual calculations. It can help students, engineers, researchers, and technicians compare measurements and work with magnetic field calculations Magnetic field strength is closely related to magnetic flux density, but the two quantities are not identical. Understanding their difference is important when interpreting magnetic measurements or working with magnetic materials.
Select the magnetic field strength units you want to convert.
Magnetic field strength (H) describes the magnetizing force produced by electric currents and magnetic materials. Its SI unit is the ampere per meter (A/m). One oersted is equal to approximately 79.57747 amperes per meter in vacuum-based unit conversion. Magnetic field strength (H) is different from magnetic flux density (B), which is measured in tesla (T).
Magnetic field strength is a measure of the magnetizing force that produces a magnetic field. It describes the intensity of the magnetic field generated by electric currents or magnetic sources.
The quantity is represented by the letter H and its SI unit is amperes per meter (A/m).
For a long straight conductor carrying an electric current, the magnetic field strength depends on the current and the distance from the conductor. For an ideal long solenoid, the field strength inside the coil depends on the number of turns per unit length and the current.
For an ideal solenoid:
Where:
H = Magnetic field strength in A/m
N = Number of turns in the coil
I = Current in amperes
l = Length of the solenoid in metres
For example, a solenoid with 500 turns, carrying 2 amperes of current over a length of 0.5 metres, produces an ideal magnetic field strength of:
Using the Magnetic Field Strength Converter is simple:
Enter the magnetic field strength value you want to convert.
Select the original unit from the From dropdown menu.
Select the target unit from the To dropdown menu.
The converter calculates the equivalent value automatically.
Review the result and use it for your calculations or reference.
For example, entering 1,000 A/m and selecting oersted as the target unit gives approximately 12.566 Oe.
The linked UnitConverters.net page supports four units for magnetic field strength conversion: ampere per meter, ampere-turn per meter, kiloampere per meter, and oersted.
Ampere per meter is the SI unit of magnetic field strength. It describes the magnetizing field produced by electric currents and magnetic sources.
It is the reference unit used for the conversions in this calculator.
Ampere-turn per meter expresses magnetic field strength in terms of coil turns and current distributed over a length.
It is numerically equivalent to ampere per meter because the number of turns is a dimensionless count.
Kiloampere per meter is a larger unit used for stronger magnetic fields.
One kiloampere per meter equals 1,000 amperes per meter.
Oersted is a CGS unit of magnetic field strength. It is named after Danish physicist Hans Christian Ørsted and is used in some magnetic material specifications and scientific references.
One oersted is approximately equal to 79.5774715459 amperes per meter.
The converter uses ampere per meter (A/m) as its reference unit. Other supported units can be converted by first expressing their values in A/m and then converting into the required target unit.
To convert A/m into Oe, multiply the value by approximately 0.01256637061.
Example: Convert 500 A/m into Oe
Therefore:
To convert oersted into A/m, multiply the value by approximately 79.5774715459.
Example: Convert 10 Oe into A/m
Therefore:
Multiply the kA/m value by 1,000.
Example: Convert 3 kA/m into A/m
Divide the A/m value by 1,000.
Example: Convert 5,000 A/m into kA/m
The following table shows the four supported units and their equivalent values using A/m as the reference.
Unit | Symbol | Equivalent in A/m |
|---|---|---|
Ampere per meter | A/m | 1 |
Ampere-turn per meter | At/m | 1 |
Kiloampere per meter | kA/m | 1,000 |
Oersted | Oe | 79.5774715459 |
Ampere per Meter (A/m) | Oersted (Oe) |
|---|---|
0.1 | 0.001256637 |
1 | 0.012566371 |
2 | 0.025132741 |
5 | 0.062831853 |
10 | 0.125663706 |
20 | 0.251327412 |
50 | 0.628318531 |
100 | 1.256637061 |
250 | 3.141592653 |
500 | 6.283185305 |
1,000 | 12.566370610 |
5,000 | 62.831853050 |
10,000 | 125.663706100 |
Oersted (Oe) | Ampere per Meter (A/m) |
|---|---|
0.1 | 7.957747 |
0.5 | 39.788736 |
1 | 79.577472 |
2 | 159.154943 |
5 | 397.887358 |
10 | 795.774715 |
20 | 1,591.549431 |
50 | 3,978.873577 |
100 | 7,957.747155 |
250 | 19,894.367886 |
500 | 39,788.735773 |
1,000 | 79,577.471546 |
Magnetic field strength and magnetic flux density are closely related, but they represent different physical quantities.
Magnetic field strength describes the magnetizing force produced by electric currents and magnetic sources. Its SI unit is ampere per meter (A/m).
It is commonly used when studying magnetic circuits, electromagnets, coils, and magnetic materials.
Magnetic flux density describes the magnetic flux passing through a unit area. Its SI unit is the tesla (T).
Where:
B = Magnetic flux density in tesla
µ = Magnetic permeability of the material
H = Magnetic field strength in A/m
For a linear, isotropic material, permeability describes how the material responds to the applied magnetic field.
Feature | Magnetic Field Strength (H) | Magnetic Flux Density (B) |
|---|---|---|
Meaning | Magnetizing field intensity | Magnetic flux per unit area |
SI unit | A/m | Tesla (T) |
CGS unit | Oersted (Oe) | Gauss (G) |
Symbol | H | B |
Depends on material response | Not in its definition | Yes, through permeability and magnetization |
Important: Do not use magnetic field strength and magnetic flux density conversion factors interchangeably. Converting between H and B requires information about the material’s magnetic properties.
Several factors influence the magnetic field strength generated by an electrical or magnetic system.
The electric current flowing through a conductor or coil affects the magnetic field it produces. Increasing current generally increases the magnetizing field when the geometry remains unchanged.
A coil with more turns can produce a stronger magnetizing field for the same current, provided its dimensions and arrangement remain the same.
For an ideal long solenoid, magnetic field strength depends on the number of turns per unit length. Increasing the coil length without increasing its turns reduces the turn density.
The magnetic field around a current-carrying conductor changes with distance. For an ideal long straight conductor, field strength decreases as the distance from the conductor increases.
Magnetic materials influence the relationship between magnetic field strength and magnetic flux density. Their permeability and magnetic characteristics affect the resulting magnetic response.
Magnetic field strength measurements are useful in several scientific, industrial, and engineering applications.
Engineers use magnetic field strength calculations to design electromagnets for lifting systems, magnetic switches, laboratory equipment, and industrial machinery.
Magnetic fields play an important role in motor operation. Engineers study field strength when designing windings, magnetic circuits, and motor components.
Transformer cores and windings depend on magnetic fields to transfer energy between electrical circuits. Magnetic field strength calculations help engineers analyze core magnetization.
Researchers measure magnetic field strength when studying the properties of materials such as iron, steel, and other magnetic substances.
Magnetic shielding systems are designed to reduce unwanted magnetic field effects. Field strength measurements help evaluate shielding performance.
Physics and engineering laboratories use magnetic field strength units when conducting experiments involving electromagnetism, magnetic materials, and magnetic circuits.
Fast conversions: Convert A/m, At/m, kA/m, and Oe without manual calculations.
Easy comparisons: Compare magnetic field strength values expressed in different measurement systems.
Consistent results: Apply standard conversion factors to different values.
Engineering convenience: Simplify calculations involving coils, magnetic materials, and electromagnetic systems.
Educational support: Understand the relationship between SI and CGS magnetic field strength units.
Time saving: Reduce repetitive calculations when working with technical specifications.
A magnetic field strength converter is useful for unit conversions, but it does not replace magnetic field measurement or engineering analysis.
It does not measure magnetic fields: A converter only changes the numerical value between units.
It does not calculate magnetic flux density: Calculating B from H requires information about magnetic permeability and material behavior.
It does not account for geometry: Real magnetic field distributions depend on the shape and arrangement of conductors and magnetic materials.
It does not model magnetic saturation: Nonlinear magnetic materials require more detailed calculations.
Correct unit selection matters: Selecting an incorrect input or output unit can produce misleading results.
Precision should be considered: Scientific and engineering work may require additional decimal places.
For professional applications, use appropriate magnetic measurement instruments and validated engineering calculations.
A magnetic field strength converter is an online tool that converts magnetic field intensity measurements between different units. It can convert values between amperes per meter, ampere-turns per meter, kiloamperes per meter, and oersteds.
The SI unit of magnetic field strength is the ampere per meter (A/m). It describes the magnetizing field produced by electric currents and magnetic sources.
One oersted is equal to approximately 79.5774715459 amperes per meter. \[ 1\ Oe = 79.5774715459\ A/m \]
Multiply the magnetic field strength value in A/m by approximately 0.01256637061. For example: \[ 100 \times 0.01256637061 = 1.256637061\ Oe \]
Multiply the oersted value by approximately 79.5774715459. For example: \[ 5 \times 79.5774715459 = 397.8873577295\ A/m \]
Both units measure magnetic field strength. Kiloampere per meter is 1,000 times larger than ampere per meter. \[ 1\ kA/m = 1000\ A/m \]
Yes. They are numerically equivalent because the number of turns is a dimensionless count. \[ 1\ At/m = 1\ A/m \]
Oersted is a CGS unit of magnetic field strength. It is used in magnetic measurements and some material specifications. One oersted equals approximately 79.5775 A/m.
Magnetic field strength (H) describes the magnetizing field and is measured in A/m. Magnetic flux density (B) describes magnetic flux per unit area and is measured in tesla. They are related through the magnetic properties of the material.
Magnetic field strength is used in electromagnet design, transformers, electric motors, magnetic material testing, magnetic shielding, and scientific research.
An online converter saves time and helps reduce manual calculation errors when changing between different magnetic field strength units. It is useful for engineering calculations, educational exercises, and technical comparisons.
A few of the most-used tools in each hub.
The Magnetic Field Strength Converter is provided for educational and general informational purposes. Conversion results are based on standard mathematical relationships between magnetic field strength units This calculator does not measure magnetic fields, determine magnetic material properties, or replace professional engineering analysis. Magnetic field strength and magnetic flux density are different quantities and should not be treated as interchangeable Always verify important calculations before using them in professional, scientific, or safety-critical applications.